Power station · ALLPOWERS

ALLPOWERS R1500

The ALLPOWERS R1500 stores 1,152 Wh and delivers 1,800 W continuous through its inverter. It accepts up to 650 W of solar via XT60. Of 11 checked solar panels, 5 fit directly and 0 with an adapter cable.

At a glance

  • Covers the first 24 hours: CPAP overnight
  • Not enough: Home blackout (only 12.5 of 24 hrs of use), Camping with cooler (only 16.5 of 24 hrs of use), Working from home (only 8.7 of 16 hrs of use), Job site (only 0.6 of 2.5 hrs of use), Fridge only (only 15.3 of 24 hrs of use)

Calculated with the simulator's starter profiles, no sun and no recharging. Calculate with your devices and solar: runtime simulator → · Details under “Runtime”

Key figures

Capacity
1,152 Wh[1, 2, 3, 4]
Cell chemistry
LFP (lithium iron phosphate)[4]
Inverter continuous output
1,800 W[4]
Surge output
3,000 W[4]
Idle draw, AC on, no load
not sourced
Total solar input, max.
650 W[1, 2, 3, 4]
Weight
16.7 kg[5]
Dimensions L × W × H
41.3 × 31.2 × 26.5 cm[5]
AC charging (120 V)
800 W[4]
Warranty (years)
5[6]
Charge cycles
3,500[6]
AC outlets
4[6]
USB-C
2 × up to 100 W[6]
USB-A
2[6]
12 V outputs
1[6]

Note: US AC charging derived from 6.8 A at 120 V[4]

Solar input

Ports (XT60)
1[1, 2, 3]
MPPT voltage range
12–60 V[1, 2, 3]
Open-circuit voltage (Voc) max.
60 V[1, 2, 3]
Input current max.
13 A[1, 2, 3]
Solar power max.
650 W[1, 2, 3]
Restrictions per source

Manual: output voltage within 60V, max 13A, 650W.

Connector per source: XT60 (MC4-to-XT60 cable included)

Runtime for typical uses

Calculated like the runtime simulator: typical scenario, no sun, full battery. Idle draw 18 W (estimate). Bars up to 72 hours.

Compatible solar panels

11 solar panels, each checked against this station's limits. Open-circuit voltage is multiplied by a cold factor of 1.10. How the check works

  • Fits directly 5
  • With adapter 0
  • Special wiring 1
  • Unclear 5
  • Doesn't fit 0
Solar panels on the XT60 input, sorted by status
Solar panelStatusConnectionQuantityCold margin
EcoFlow 400W Portable Solar Panel · 400 WFits directly
  1. MC4
  2. XT60 (cable included with station)
up to 1sufficient
EcoFlow NextGen 220W Bifacial Portable Solar Panel · 220 WFits directly
  1. MC4
  2. XT60 (cable included with station)
up to 2sufficient
BLUETTI PV200 · 200 WFits directly
  1. MC4
  2. XT60 (cable included with station)
up to 2sufficient
EcoFlow 110W Portable Solar Panel · 110 WFits directly
  1. MC4
  2. XT60 (cable included with station)
up to 4sufficient
Renogy 100W 12V Flexible Monocrystalline · 100 WFits directly
  1. MC4
  2. XT60 (cable included with station)
up to 4sufficient
Jackery SolarSaga 200W (JS-200D) · 200 WSpecial wiring
  1. DC8020
  2. MC4
or
  1. DC8020
  2. XT60 third-party adapter
up to 2sufficient
LONGi Hi-MO 6 LR5-54HTH-430M · 430 WUnclear
  1. MC4
  2. XT60 (cable included with station)
up to 1sufficient
Anker SOLIX PS400 (A2437) · 400 WUnclear
  1. MC4
  2. XT60 (cable included with station)
up to 1below 10%
Anker 531 Solar Panel 200W · 200 WUnclear
  1. XT60 (panel)
  2. XT60 input
up to 1can't be checked
Goal Zero Nomad 200 · 200 WUnclear
  1. Anderson Powerpole (HPP)
  2. XT60 third-party adapter
up to 1sufficient
Jackery SolarSaga 100 Air · 100 WUnclear–up to 3sufficient
Check notes per panel
EcoFlow 400W Portable Solar Panel

Voc 48V x1 = 48.0V; cold-adjusted 52.8V <= 60V. Isc 11A <= 13A (allows 1 string(s) in parallel per port).

Max per port: 1 in series x 1 parallel string(s); ports: 1.

Another R1500 manual revision states 95V (12-95V); conservative 60V used until hardware revision is identified.

manuals.plus/allpower/r1500-portable-power-stat… · device.report/manual/15071721 · device.report/manuals/allpowers-r1500-solar-gen… · us.ecoflow.com/products/400w-portable-solar-pan…

EcoFlow NextGen 220W Bifacial Portable Solar Panel

Voc 21.5V x1 = 21.5V; cold-adjusted 23.7V <= 60V. Isc 12.4A <= 13A (allows 1 string(s) in parallel per port).

Max per port: 2 in series x 1 parallel string(s); ports: 1.

Another R1500 manual revision states 95V (12-95V); conservative 60V used until hardware revision is identified.

manuals.plus/allpower/r1500-portable-power-stat… · device.report/manual/15071721 · device.report/manuals/allpowers-r1500-solar-gen… · ca.ecoflow.com/products/220w-bifacial-portable-…

BLUETTI PV200

Voc 26.1V x1 = 26.1V; cold-adjusted 28.7V <= 60V. Isc 10.3A <= 13A (allows 1 string(s) in parallel per port).

Max per port: 2 in series x 1 parallel string(s); ports: 1.

Another R1500 manual revision states 95V (12-95V); conservative 60V used until hardware revision is identified.

manuals.plus/allpower/r1500-portable-power-stat… · device.report/manual/15071721 · device.report/manuals/allpowers-r1500-solar-gen… · bluetti.com/wp-content/uploads/2024/07/PV200-Us… · bluettipower.eu/products/bluetti-sp200

EcoFlow 110W Portable Solar Panel

Voc 21.8V x1 = 21.8V; cold-adjusted 24.0V <= 60V. Isc 6.5A <= 13A (allows 2 string(s) in parallel per port).

Max per port: 2 in series x 2 parallel string(s); ports: 1.

Another R1500 manual revision states 95V (12-95V); conservative 60V used until hardware revision is identified.

manuals.plus/allpower/r1500-portable-power-stat… · device.report/manual/15071721 · device.report/manuals/allpowers-r1500-solar-gen… · us.ecoflow.com/products/110w-portable-solar-pan…

Renogy 100W 12V Flexible Monocrystalline

Voc 24.4V x1 = 24.4V; cold-adjusted 26.8V <= 60V. Isc 5.16A <= 13A (allows 2 string(s) in parallel per port).

Max per port: 2 in series x 2 parallel string(s); ports: 1.

Another R1500 manual revision states 95V (12-95V); conservative 60V used until hardware revision is identified.

manuals.plus/allpower/r1500-portable-power-stat… · device.report/manual/15071721 · device.report/manuals/allpowers-r1500-solar-gen… · renogy.com/100-watt-12-volt-flexible-monocrysta…

Jackery SolarSaga 200W (JS-200D)

Voc 24.8V x1 = 24.8V; cold-adjusted 27.3V <= 60V. Isc 11.2A <= 13A (allows 1 string(s) in parallel per port).

Max per port: 2 in series x 1 parallel string(s); ports: 1. Not manufacturer-documented; verify polarity with a multimeter before connecting.

Another R1500 manual revision states 95V (12-95V); conservative 60V used until hardware revision is identified.

manuals.plus/allpower/r1500-portable-power-stat… · device.report/manual/15071721 · device.report/manuals/allpowers-r1500-solar-gen… · manualslib.com/manual/3478346/Jackery-Solarsaga… · jackery.com/products/solarsaga-200w-solar-panel

LONGi Hi-MO 6 LR5-54HTH-430M

Voc 39.13V x1 = 39.1V; cold-adjusted 43.0V <= 60V. Isc 14.15A exceeds 13A and manufacturer does not document current limiting for over-current panels.

Max per port: 1 in series x 1 parallel string(s); ports: 1.

Another R1500 manual revision states 95V (12-95V); conservative 60V used until hardware revision is identified.

manuals.plus/allpower/r1500-portable-power-stat… · device.report/manual/15071721 · device.report/manuals/allpowers-r1500-solar-gen…

Anker SOLIX PS400 (A2437)

STC Voc 57.6V is within 60V but cold-adjusted 63.4V exceeds it (<10% headroom). Isc 8.75A <= 13A (allows 1 string(s) in parallel per port).

Max per port: 1 in series x 1 parallel string(s); ports: 1.

Another R1500 manual revision states 95V (12-95V); conservative 60V used until hardware revision is identified.

manuals.plus/allpower/r1500-portable-power-stat… · device.report/manual/15071721 · device.report/manuals/allpowers-r1500-solar-gen… · service.ankersolix.com/product-description/a085… · ankersolix.com/products/400w-portable-solar-pan…

Anker 531 Solar Panel 200W

Voc not published; voltage limit cannot be verified. Imp (Isc unpublished) 4.17A <= 13A (allows 3 string(s) in parallel per port). Isc unpublished; parallel count uses Imp and is optimistic.

Max per port: 1 in series x 3 parallel string(s); ports: 1.

Another R1500 manual revision states 95V (12-95V); conservative 60V used until hardware revision is identified.

manuals.plus/allpower/r1500-portable-power-stat… · device.report/manual/15071721 · device.report/manuals/allpowers-r1500-solar-gen… · ankersolix.com/ca/products/a24321a1-free

Goal Zero Nomad 200

Voc 23.0V x1 = 23.0V; cold-adjusted 25.3V <= 60V. port-rated current bound 14A exceeds 13A and manufacturer does not document current limiting for over-current panels.

Max per port: 2 in series x 1 parallel string(s); ports: 1. Not manufacturer-documented; verify polarity.

Another R1500 manual revision states 95V (12-95V); conservative 60V used until hardware revision is identified.

manuals.plus/allpower/r1500-portable-power-stat… · device.report/manual/15071721 · device.report/manuals/allpowers-r1500-solar-gen… · goalzero.eu/en/product/goal-zero-nomad-200

Jackery SolarSaga 100 Air

Voc 29.7V x1 = 29.7V; cold-adjusted 32.7V <= 60V. Isc 4.1A <= 13A (allows 3 string(s) in parallel per port).

Max per port: 1 in series x 3 parallel string(s); ports: 1. Panel connector type not confirmed in sources; connector chain cannot be validated.

Another R1500 manual revision states 95V (12-95V); conservative 60V used until hardware revision is identified.

manuals.plus/allpower/r1500-portable-power-stat… · device.report/manual/15071721 · device.report/manuals/allpowers-r1500-solar-gen… · jackery.com/products/jackery-explorer-1000-plus…

Keep going with this station

Sources

Manufacturer pages and manuals take priority. Retailer listings appear only where no manufacturer source exists.

  1. Manufacturer manual, third-party host manuals.plus/allpower/r1500-portable-power-station-manual
  2. Manufacturer manual, third-party host device.report/manual/15071721
  3. Manufacturer manual, third-party host device.report/manuals/allpowers-r1500-solar-generator-manual
  4. Manufacturer iallpowers.eu/s/RevealTheR1500
  5. Manufacturer iallpowers.eu/products/allpowers-r1500-portable-home-backup-pow…
  6. Manufacturer iallpowers.com/products/allpowers-r1500-portable-home-backup-po…

Checked on