Power station · Zendure
Zendure SuperBase Pro 2000
The Zendure SuperBase Pro 2000 stores 2,096 Wh and delivers 2,000 W continuous through its inverter. It accepts up to 2,400 W of solar via XT60 + AC inlet (PVMax). Of 11 checked solar panels, 5 fit directly and 0 with an adapter cable.
At a glance
- Covers the first 24 hours: Camping with cooler, Working from home, CPAP overnight
- Not enough: Home blackout (only 19.9 of 24 hrs of use), Fridge only (only 23.4 of 24 hrs of use)
- Unclear: Job site (startup unclear)
Calculated with the simulator's starter profiles, no sun and no recharging. Calculate with your devices and solar: runtime simulator → · Details under “Runtime”
Key figures
- Cell chemistry
- NMC (lithium nickel manganese cobalt oxide)[4]
- Inverter continuous output
- 2,000 W[4]
- Boost for heating loads (not a startup rating)
- 3,000 W[2]
- Idle draw, AC on, no load
- not sourced
- Weight
- 21.2 kg[2]
- Dimensions L × W × H
- 44.6 × 27.6 × 35.2 cm[2]
- AC charging (120 V)
- 1,800 W[4]
- Warranty (years)
- 2[2]
- Charge cycles
- 3,000 to 60%[2]
- AC outlets
- 6[2]
- USB-C
- 4 × up to 100 W[2]
- USB-A
- 2[2]
- 12 V outputs
- 1[2]
Note: XT60 600 W, 1800 W only with high-voltage panels; US clearance; 3000 W is AmpUp (voltage reduction), no real surge rating is documented by the manufacturer[4, 2]
Solar input
XT60 input
Restrictions per source
12-60Vmp, Voc must stay within 75V, 600W. Manual solar section states 12-160Vmp, 11A max for solar input without splitting per port; 11A applied to XT60 (interpretation).
Connector per source: XT60 (MC4-to-XT60 3m cable included)
AC inlet (PVMax) input
Restrictions per source
60-160Vmp, Voc within 200V, 11A, 1800W. Requires series strings; can run in parallel with the XT60 input (2400W total).
Connector per source: AC inlet used as PV input via Zendure MC4-to-AC cable (included)
Runtime for typical uses
Calculated like the runtime simulator: typical scenario, no sun, full battery. Idle draw 22 W (estimate). Bars up to 72 hours.
Compatible solar panels
11 solar panels, each checked against this station's limits. Open-circuit voltage is multiplied by a cold factor of 1.10. How the check works
XT60 input
- Fits directly 5
- With adapter 0
- Special wiring 0
- Unclear 6
- Doesn't fit 0
| Solar panel | Status | Connection | Quantity | Cold margin |
|---|---|---|---|---|
| Anker SOLIX PS400 (A2437) · 400 W | Fits directly |
| up to 1 | sufficient |
| EcoFlow 400W Portable Solar Panel · 400 W | Fits directly |
| up to 1 | sufficient |
| BLUETTI PV200 · 200 W | Fits directly |
| up to 2 | sufficient |
| EcoFlow 110W Portable Solar Panel · 110 W | Fits directly |
| up to 3 | sufficient |
| Renogy 100W 12V Flexible Monocrystalline · 100 W | Fits directly |
| up to 4 | sufficient |
| LONGi Hi-MO 6 LR5-54HTH-430M · 430 W | Unclear |
| up to 1 | sufficient |
| EcoFlow NextGen 220W Bifacial Portable Solar Panel · 220 W | Unclear |
| up to 1 | sufficient |
| Anker 531 Solar Panel 200W · 200 W | Unclear |
| up to 1 | can't be checked |
| Goal Zero Nomad 200 · 200 W | Unclear |
| up to 1 | sufficient |
| Jackery SolarSaga 200W (JS-200D) · 200 W | Unclear |
| up to 1 | sufficient |
| Jackery SolarSaga 100 Air · 100 W | Unclear | – | up to 4 | sufficient |
AC inlet (PVMax) input
- Fits directly 0
- With adapter 0
- Special wiring 5
- Unclear 6
- Doesn't fit 0
| Solar panel | Status | Connection | Quantity | Cold margin |
|---|---|---|---|---|
| Anker SOLIX PS400 (A2437) · 400 W | Special wiring |
| up to 3 | sufficient |
| EcoFlow 400W Portable Solar Panel · 400 W | Special wiring |
| up to 3 | sufficient |
| BLUETTI PV200 · 200 W | Special wiring |
| up to 6 | sufficient |
| EcoFlow 110W Portable Solar Panel · 110 W | Special wiring |
| up to 8 | sufficient |
| Renogy 100W 12V Flexible Monocrystalline · 100 W | Special wiring |
| up to 14 | sufficient |
| LONGi Hi-MO 6 LR5-54HTH-430M · 430 W | Unclear |
| up to 1 | sufficient |
| EcoFlow NextGen 220W Bifacial Portable Solar Panel · 220 W | Unclear |
| up to 1 | sufficient |
| Anker 531 Solar Panel 200W · 200 W | Unclear |
| up to 1 | can't be checked |
| Goal Zero Nomad 200 · 200 W | Unclear |
| up to 1 | sufficient |
| Jackery SolarSaga 200W (JS-200D) · 200 W | Unclear |
| up to 1 | sufficient |
| Jackery SolarSaga 100 Air · 100 W | Unclear | – | up to 12 | sufficient |
Check notes per panel
- Anker SOLIX PS400 (A2437) (XT60)
Voc 57.6V x1 = 57.6V; cold-adjusted 63.4V <= 75V. Isc 8.75A <= 11A (allows 1 string(s) in parallel per port).
Max per port: 1 in series x 1 parallel string(s); ports: 1.
zendure.com/pages/superbase-pro-2000-us-user-ma… · zendure.com/products/superbase-pro-2000 · service.ankersolix.com/product-description/a085… · ankersolix.com/products/400w-portable-solar-pan…
- EcoFlow 400W Portable Solar Panel (XT60)
Voc 48V x1 = 48.0V; cold-adjusted 52.8V <= 75V. Isc 11A <= 11A (allows 1 string(s) in parallel per port).
Max per port: 1 in series x 1 parallel string(s); ports: 1.
zendure.com/pages/superbase-pro-2000-us-user-ma… · zendure.com/products/superbase-pro-2000 · us.ecoflow.com/products/400w-portable-solar-pan…
- BLUETTI PV200 (XT60)
Voc 26.1V x1 = 26.1V; cold-adjusted 28.7V <= 75V. Isc 10.3A <= 11A (allows 1 string(s) in parallel per port).
Max per port: 2 in series x 1 parallel string(s); ports: 1.
zendure.com/pages/superbase-pro-2000-us-user-ma… · zendure.com/products/superbase-pro-2000 · bluetti.com/wp-content/uploads/2024/07/PV200-Us… · bluettipower.eu/products/bluetti-sp200
- EcoFlow 110W Portable Solar Panel (XT60)
Voc 21.8V x1 = 21.8V; cold-adjusted 24.0V <= 75V. Isc 6.5A <= 11A (allows 1 string(s) in parallel per port).
Max per port: 3 in series x 1 parallel string(s); ports: 1.
zendure.com/pages/superbase-pro-2000-us-user-ma… · zendure.com/products/superbase-pro-2000 · us.ecoflow.com/products/110w-portable-solar-pan…
- Renogy 100W 12V Flexible Monocrystalline (XT60)
Voc 24.4V x1 = 24.4V; cold-adjusted 26.8V <= 75V. Isc 5.16A <= 11A (allows 2 string(s) in parallel per port).
Max per port: 2 in series x 2 parallel string(s); ports: 1.
zendure.com/pages/superbase-pro-2000-us-user-ma… · zendure.com/products/superbase-pro-2000 · renogy.com/100-watt-12-volt-flexible-monocrysta…
- LONGi Hi-MO 6 LR5-54HTH-430M (XT60)
Voc 39.13V x1 = 39.1V; cold-adjusted 43.0V <= 75V. Isc 14.15A exceeds 11A and manufacturer does not document current limiting for over-current panels.
Max per port: 1 in series x 1 parallel string(s); ports: 1.
zendure.com/pages/superbase-pro-2000-us-user-ma… · zendure.com/products/superbase-pro-2000
- EcoFlow NextGen 220W Bifacial Portable Solar Panel (XT60)
Voc 21.5V x1 = 21.5V; cold-adjusted 23.7V <= 75V. Isc 12.4A exceeds 11A and manufacturer does not document current limiting for over-current panels.
Max per port: 3 in series x 1 parallel string(s); ports: 1.
zendure.com/pages/superbase-pro-2000-us-user-ma… · zendure.com/products/superbase-pro-2000 · ca.ecoflow.com/products/220w-bifacial-portable-…
- Anker 531 Solar Panel 200W (XT60)
Voc not published; voltage limit cannot be verified. Imp (Isc unpublished) 4.17A <= 11A (allows 2 string(s) in parallel per port). Isc unpublished; parallel count uses Imp and is optimistic.
Max per port: 1 in series x 2 parallel string(s); ports: 1.
zendure.com/pages/superbase-pro-2000-us-user-ma… · zendure.com/products/superbase-pro-2000 · ankersolix.com/ca/products/a24321a1-free
- Goal Zero Nomad 200 (XT60)
Voc 23.0V x1 = 23.0V; cold-adjusted 25.3V <= 75V. port-rated current bound 14A exceeds 11A and manufacturer does not document current limiting for over-current panels.
Max per port: 2 in series x 1 parallel string(s); ports: 1. Not manufacturer-documented; verify polarity.
zendure.com/pages/superbase-pro-2000-us-user-ma… · zendure.com/products/superbase-pro-2000 · goalzero.eu/en/product/goal-zero-nomad-200
- Jackery SolarSaga 200W (JS-200D) (XT60)
Voc 24.8V x1 = 24.8V; cold-adjusted 27.3V <= 75V. Isc 11.2A exceeds 11A and manufacturer does not document current limiting for over-current panels.
Max per port: 2 in series x 1 parallel string(s); ports: 1. Not manufacturer-documented; verify polarity with a multimeter before connecting.
zendure.com/pages/superbase-pro-2000-us-user-ma… · zendure.com/products/superbase-pro-2000 · manualslib.com/manual/3478346/Jackery-Solarsaga… · jackery.com/products/solarsaga-200w-solar-panel
- Jackery SolarSaga 100 Air (XT60)
Voc 29.7V x1 = 29.7V; cold-adjusted 32.7V <= 75V. Isc 4.1A <= 11A (allows 2 string(s) in parallel per port).
Max per port: 2 in series x 2 parallel string(s); ports: 1. Panel connector type not confirmed in sources; connector chain cannot be validated.
zendure.com/pages/superbase-pro-2000-us-user-ma… · zendure.com/products/superbase-pro-2000 · jackery.com/products/jackery-explorer-1000-plus…
- Anker SOLIX PS400 (A2437) (AC inlet (PVMax))
Voc 57.6V x2 = 115.2V; cold-adjusted 126.7V <= 200V. Isc 8.75A <= 11A (allows 1 string(s) in parallel per port).
Max per port: 3 in series x 1 parallel string(s); ports: 1. Minimum 2 panels in series required to reach 60V MPPT minimum. Minimum 60Vmp requires series string.
zendure.com/pages/superbase-pro-2000-us-user-ma… · manuals.plus/zendure/zdsbp2000-superbase-pro-20… · service.ankersolix.com/product-description/a085… · ankersolix.com/products/400w-portable-solar-pan…
- EcoFlow 400W Portable Solar Panel (AC inlet (PVMax))
Voc 48V x2 = 96.0V; cold-adjusted 105.6V <= 200V. Isc 11A <= 11A (allows 1 string(s) in parallel per port).
Max per port: 3 in series x 1 parallel string(s); ports: 1. Minimum 2 panels in series required to reach 60V MPPT minimum. Minimum 60Vmp requires series string.
zendure.com/pages/superbase-pro-2000-us-user-ma… · manuals.plus/zendure/zdsbp2000-superbase-pro-20… · us.ecoflow.com/products/400w-portable-solar-pan…
- BLUETTI PV200 (AC inlet (PVMax))
Voc 26.1V x3 = 78.3V; cold-adjusted 86.1V <= 200V. Isc 10.3A <= 11A (allows 1 string(s) in parallel per port).
Max per port: 6 in series x 1 parallel string(s); ports: 1. Minimum 3 panels in series required to reach 60V MPPT minimum. Minimum 60Vmp requires series string.
zendure.com/pages/superbase-pro-2000-us-user-ma… · manuals.plus/zendure/zdsbp2000-superbase-pro-20… · bluetti.com/wp-content/uploads/2024/07/PV200-Us… · bluettipower.eu/products/bluetti-sp200
- EcoFlow 110W Portable Solar Panel (AC inlet (PVMax))
Voc 21.8V x4 = 87.2V; cold-adjusted 95.9V <= 200V. Isc 6.5A <= 11A (allows 1 string(s) in parallel per port).
Max per port: 8 in series x 1 parallel string(s); ports: 1. Minimum 4 panels in series required to reach 60V MPPT minimum. Minimum 60Vmp requires series string.
zendure.com/pages/superbase-pro-2000-us-user-ma… · manuals.plus/zendure/zdsbp2000-superbase-pro-20… · us.ecoflow.com/products/110w-portable-solar-pan…
- Renogy 100W 12V Flexible Monocrystalline (AC inlet (PVMax))
Voc 24.4V x3 = 73.2V; cold-adjusted 80.5V <= 200V. Isc 5.16A <= 11A (allows 2 string(s) in parallel per port).
Max per port: 7 in series x 2 parallel string(s); ports: 1. Minimum 3 panels in series required to reach 60V MPPT minimum. Minimum 60Vmp requires series string.
zendure.com/pages/superbase-pro-2000-us-user-ma… · manuals.plus/zendure/zdsbp2000-superbase-pro-20… · renogy.com/100-watt-12-volt-flexible-monocrysta…
- LONGi Hi-MO 6 LR5-54HTH-430M (AC inlet (PVMax))
Voc 39.13V x2 = 78.3V; cold-adjusted 86.1V <= 200V. Isc 14.15A exceeds 11A and manufacturer does not document current limiting for over-current panels.
Max per port: 4 in series x 1 parallel string(s); ports: 1. Minimum 2 panels in series required to reach 60V MPPT minimum. Minimum 60Vmp requires series string.
zendure.com/pages/superbase-pro-2000-us-user-ma… · manuals.plus/zendure/zdsbp2000-superbase-pro-20…
- EcoFlow NextGen 220W Bifacial Portable Solar Panel (AC inlet (PVMax))
Voc 21.5V x4 = 86.0V; cold-adjusted 94.6V <= 200V. Isc 12.4A exceeds 11A and manufacturer does not document current limiting for over-current panels.
Max per port: 8 in series x 1 parallel string(s); ports: 1. Minimum 4 panels in series required to reach 60V MPPT minimum. Minimum 60Vmp requires series string.
zendure.com/pages/superbase-pro-2000-us-user-ma… · manuals.plus/zendure/zdsbp2000-superbase-pro-20… · ca.ecoflow.com/products/220w-bifacial-portable-…
- Anker 531 Solar Panel 200W (AC inlet (PVMax))
Voc not published; voltage limit cannot be verified. Imp (Isc unpublished) 4.17A <= 11A (allows 2 string(s) in parallel per port). Isc unpublished; parallel count uses Imp and is optimistic.
Max per port: 1 in series x 2 parallel string(s); ports: 1. Minimum 2 panels in series required to reach 60V MPPT minimum. Not manufacturer-documented.
zendure.com/pages/superbase-pro-2000-us-user-ma… · manuals.plus/zendure/zdsbp2000-superbase-pro-20… · ankersolix.com/ca/products/a24321a1-free
- Goal Zero Nomad 200 (AC inlet (PVMax))
Voc 23.0V x4 = 92.0V; cold-adjusted 101.2V <= 200V. port-rated current bound 14A exceeds 11A and manufacturer does not document current limiting for over-current panels.
Max per port: 7 in series x 1 parallel string(s); ports: 1. Minimum 4 panels in series required to reach 60V MPPT minimum. Not manufacturer-documented.
zendure.com/pages/superbase-pro-2000-us-user-ma… · manuals.plus/zendure/zdsbp2000-superbase-pro-20… · goalzero.eu/en/product/goal-zero-nomad-200
- Jackery SolarSaga 200W (JS-200D) (AC inlet (PVMax))
Voc 24.8V x3 = 74.4V; cold-adjusted 81.8V <= 200V. Isc 11.2A exceeds 11A and manufacturer does not document current limiting for over-current panels.
Max per port: 7 in series x 1 parallel string(s); ports: 1. Minimum 3 panels in series required to reach 60V MPPT minimum. Not manufacturer-documented.
zendure.com/pages/superbase-pro-2000-us-user-ma… · manuals.plus/zendure/zdsbp2000-superbase-pro-20… · manualslib.com/manual/3478346/Jackery-Solarsaga… · jackery.com/products/solarsaga-200w-solar-panel
- Jackery SolarSaga 100 Air (AC inlet (PVMax))
Voc 29.7V x3 = 89.1V; cold-adjusted 98.0V <= 200V. Isc 4.1A <= 11A (allows 2 string(s) in parallel per port).
Max per port: 6 in series x 2 parallel string(s); ports: 1. Minimum 3 panels in series required to reach 60V MPPT minimum. Panel connector type not confirmed in sources; connector chain cannot be validated.
zendure.com/pages/superbase-pro-2000-us-user-ma… · manuals.plus/zendure/zdsbp2000-superbase-pro-20… · jackery.com/products/jackery-explorer-1000-plus…
Keep going with this station
Sources
Manufacturer pages and manuals take priority. Retailer listings appear only where no manufacturer source exists.
- Manufacturer zendure.com/pages/superbase-pro-2000-us-user-manual-english
- Manufacturer zendure.com/products/superbase-pro-2000
- Manufacturer manual, third-party host manuals.plus/zendure/zdsbp2000-superbase-pro-2000-portable-powe…
- Retailer listing adorama.com/znzdsbp2bkus.html
Checked on